explosion and moisture proof heat detectorThe EPBMPB Series Explosion/Moisture Proof Heat Detectors.

CLICK HERE- CLOSEST PRODUCT OFFERING FOR THE EPBMPB SERIES

**[EPBMPB Series is discontinued]**

explosion proof pull stationXAL53 Explosion Proof Pull Station. UL Listed for Class I, Division 1, Groups C & D, Class II, Divisions 1 & 2, Groups E, F, & G & CLASS III Locations.

weather/moisture prrof heat detectorThe WPBMPB SERIES WEATHER/MOISTURE PROOF HEAT DETECTORS

 CLOSEST PRODUCT OFFERING FOR THE WPBMPB

**[WPBMPB Series is discontinued]***

explosion proof photo electric smoke detector edwards signaling Explosion-Proof Photo-Electric Smoke Detector

V9006-0001-013


EPBMPB SERIES EXPLOSION-PROOF HEAT DETECTORS

WPBMPB SERIES WEATHER/MOISTURE HEAT DETECTOS

The EPBMPB, WPBMPB heat sensors are normally-open devices designed to close an electrical circuit upon activation.  Sensors use dual action, electric fire detection thermostats that employ two independent methods of detection:  rate-of-rise and fixed temperature.  Models are available in configurations that include fixed temperature and combination rate-of-rise/fixed temperature sensors. 

The WPBMPB Series Weather/Moisture Proof Heat Detectors consist of a cast metal box, gasket and special steel cover plate integrated with the sensor.  A crossed wire guard is added for extra protection.  The emerging wire points are sealed with epoxy, increasing resistance to moisture.  The cast metal box has four wide entrances for 1/2" rigid conduit.  The unit offers combined protection against weather and condensation in the conduit.

The EPBMPB Series Explosion/Moisture Proof Heat Detectors consist of a cast metal box, cover plate, moisture resistant gasket and a modified heat sensor.  The back box has two opposing wire entrances threaded for 1/2-inch rigid conduit.  The box, cover and base are precision machined for extremely close tolerance fit.

FEATURES

  • Rate-of-rise and fixed temperature models
  • Compact, simple design unaffected by vibration
  • Large terminals and wireways simplify wiring in open or concealed applications
  • No exposed metal parts carry current
  • All electrical contacts are all silver-clad
  • All metal parts are brass of aluminum, mounted on a durable, phonelic base

AGENCY APPROVALS

  • Designed to meet Class I, Div. I, Groups C & D; Class II, Div I, Groups E, F, & G (EPBMPB Models only)
  • UL Listed
  • FM Approved
  • CSFM Listed
  • MEA Listed
  • ULC Listed

CLOSEST PRODUCT OFFERING FOR THE EPBMPB SERIES  

**[EPBMPB Series is discontinued]**

Model

Description

Price

Explosion/moisture proof models
EPBMPB501 Rate-of-rise and fixed temperature (136F & 58C)

 

EPBMPB502 Rate-of-rise and fixed temperature (190F & 88C)

 

EPBMPB503 Fixed temperature (136F & 58C)

 

EPBMPB504 Fixed temperature (190F & 88C)

 

explosion/moisture proof heat detector

CLOSEST PRODUCT OFFERING FOR THE EPBMPB SERIES

**[EPBMPB Series is discontinued]**


 

 

CLOSEST PRODUCT OFFERING FOR THE WPBMPB  

**[WPBMPB Series is discontinued]***

WPBMPB501 Rate-of-rise and fixed temperature (136F &58C)  
WPBMPB502 Rate-of-rise and fixed temperature (190F & 88C)  
WPBMPB503 Fixed temperature (136F & 58C)  
WPBMPB504 Fixed temperature (190F & 88C)  

weatherproof heat detector

CLOSEST PRODUCT OFFERING FOR THE WPBMPB

**[WPBMPB Series is discontinued]***

 


EXPLOSION PROOF PULL STATION/XAL-53

The XAL Hazardous Location Fire Alarm Pull Station is activated by lifting the front cover and pulling down the ring.  This quick, easy to use two-step process prevents unintentional operation.  Unit is reset by depressing shaft and returning plate to original position.

Suitable for hazardous locations where flammable gases or vapors, combustible dusts or easily ignitable  fibers or flyings are present.  Ideal for installation at petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled or stored.  Used in areas where emergency control of fire alarm or signal circuits is required.

FEATURES

  • Enclosure is made of copper free aluminum alloy
  • Conduit openings are 3/4" NPT feed through
  • Red, textured powder epoxy paint finish is standard on box and cover and provides high visibility.
  • Universal (1) normally open and (1) normally closed contact furnished standard
  • Bilingual nameplates included per CSA requirement
  • Internal ground screw is standard

AGENCY APPROVALS

  • UL Listed for Class I, Divisions 1 & 2, Groups C & D; Class II, Divisions 1 & 2, Groups E, F, & G; and Class III locations
  • ULC Listed
  • CSA Certified
  • CSFM Listed

Volts

Make Amps

VA

120

60

7200

240

30

7200

480

15

7200

600

12

7200

explosion proof pull stationsWEB SPECIAL PRICE: XAL53 @ $ 689.99 EACH

 

EXPLOSION-PROOF PHOTO-ELECTRIC SMOKE DETECTOR V9006-001-013

The V9006-001-013 Explosion proof Smoke Detector has been designed for use in hazardous industrial and commercial locations.  It is a sensitive yet rugged, state-of-the-art, life safety device.  The detector is designed to operate effectively with both slow smoldering and fast burning fires.

The V9006-001-013 detector uses a solid state infrared emitting diode (IRED) and a light sensing photovoltaic cell arranged in a labyrinth assembly.  Such an assembly permits free access to smoke but restricts external light.  A light beam from an IRED with associated optics is projected across the interior of the labyrinth into a light catcher.  A recessed photodiode provides voltage for amplification to "alarm signal" level.  The main enclosure of the detector contains the electronics, alarm relay, supervision relay and facilities for connection to system wiring.

For use in combustible storage facilities, munitions manufacturing, volatile chemical storage, chemical processing plants, petroleum refineries, turbine enclosures or any hazardous location where photoelectric smoke detection is required.

Alarm System Connections

Each detector contains one set of Form A (SPST) N/O contacts for connection to the alarm initiating circuit and a set of (SPST) N/C power supervision contacts.

The detector locks in on alarm and has a lock-in alarm indicator (LED) on the outer surface of the housing.  Detector reset is achieved by momentary interruption of power.

FEATURES

  • Labyrinth assembly
  • Self-checking components
  • Infrared (IRED) light emitting diode as light source

AGENCY APPROVALS

  • VDE Certified
  • Designed to meet Class I, Div 1, Groups C & D; Class II, Div 1, Groups E, F & G

SPECIFICATIONS

  • 20-28V DC
  • Typical current at 77ºF- 10mA
  • Alarm current - 35mA
  • Standby current - 10mA
  • Residual ripple less than 2% of DC input
  • Temperature range-4ºF to 140ºF
  • Max. air velocity 3960 FPM
  • Contact rating 2A at 30V DC, 0.5 at 125V AC
  • Dim. 5 5/16" Dia x 3 1/2" deep
  • Junction box-3/4" Hubs

explosion proof photo electric smoke detectorV9006-001-013 Web Price: $3,999.99 Each

Approximate Lead Time on the V9006-001-013   [3-4 Weeks].

 

 

1-800-843-6036

Click Here to Email Us

   OnLine Order

Supported Browsers IE, SAFARI, CHROME

More Edwards Signaling Solutions

 

 

Prices are subject to change without notice. Inventory is subject to prior sale. Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product.

Not Responsible for errors in print, verify all data with us or manufacturer. Terms & Conditions of sale apply, for a copy contact us.

Products may be discontinued without notice.

Visit midsouthelectronics.com for more electronic solutions

Visit midsouthglobal.net